Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We follow our enterprise spirit of "Quality, Efficiency, Innovation and Integrity". We aim to create much more worth for our buyers with our abundant resources, highly developed machinery, experienced workers and great providers for Bod Test Kit , Best Turbidity Meter , Chemical Oxygen Demand , We warmly welcome your participation based on mutual benefits in the near future.
Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua Detail:

Product Introduction

It is important for wastewater treatment plants to measure Biochemical Oxygen Demand (BOD) to quantify the potential for effluent water to deplete the oxygen in the receiving stream. If not controlled, discharged wastewater can rob the receiving stream of this oxygen and have significant negative effects on the environment. Measuring BOD is required as part of the environmental discharge permit and is an important parameter to evaluate the effectiveness of the wastewater treatment operation.

LH-BOD601 BOD instrument with BOD reagent for Biochemical Oxygen Demand testing help wastewater treatment plants achieve optimum BOD measurement while allowing keeping a high level of operational efficiency. It is used manometric method, can choose 1-30 days testing period.

Functional characteristics

1. At the same time can be measured in a sample of 6.
2. Automatic daily print data.
3. Color liquid crystal display screen, the sample values with different colors, intuitive and clear.
4. Has a plurality of stirring mode (batch, continuous), prolong the service life of the instrument.
5. The culture period can be adjusted according to the demand, can choose 1-30 days.
6. To view the test process and the test data, no historical data.

Technical Parameters

Instrument name

Biochemical Oxygen Demand (BOD5) Instrument

Instrument model

LH-BOD601

Measurement range

0-4000mg/L

Measuring error

±5%

Record interval

6 minutes – 3 hours/time

Cycle length

1-30days

Measure amount

6

Culture bottle volume

580ml

Data storage

20 years

Communication

USB transmission, infrared transmission (optional)

Culture temperature

20±1

Working power

110-230V  50-60HZ

Rated power

24W

Advantage

● Wide measuring range 0-4000 mg/L
● Built-in thermal printer
● Intelligent analysis of data
● No reagents need for routine water sample testing

Usage

Sewage treatment plants, monitoring bureaus, environmental treatment companies, chemical plants, pharmaceutical plants, textile plants, university laboratories, food and beverage plants, etc.

FAQ

1. Are you a factory or trading company?
We are a factory.
2. MOQ?
We don’t have MOQ limit, you can order any quantity you want.
If you need it with your specification, logo, packing, etc, please negotiate with us.
3. Can I add my logo on the machine?
Yes,OEM is available for us.
4. How can i get the after-service?
We will send you the spare parts by free if the problems caused by us.
If it is the men-made problems,we also send the spare parts,but you should pay.
5. Do you have inspection procedures for these machine?
100% self-inspection before packing
6. Delivery date?
5-15 days
7. Payment Method?
L/C at sight, T/T, Credit card, paypal
8. Shipping?
a. International Experess: DHL/TNT/FEDEX/UPS (For sample)
b. By air (For sample orders.)
c. By sea (15-45days), port of loading: Shanghai
d. By domestic logistics to your forwarder. (2-3days)


Product detail pictures:

Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures


Related Product Guide:

With our loaded practical experience and thoughtful solutions, we now have been identified for a trusted provider for numerous intercontinental consumers for Super Purchasing for Skalar Bod Analyzer - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua , The product will supply to all over the world, such as: Swansea, Albania, Croatia, Till now, the goods list has been updated regularly and attracted clients from around the globe. Detailed facts is often obtained in our web-site and you'll be served with premium quality consultant service by our after-sale group. They are going to help you get comprehensive acknowledge about our products and make a satisfied negotiation. Company go to to our factory in Brazil is also welcome at any time. Hope to obtain your inquiries for any pleased co-operation.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Sabrina from Ukraine - 2017.07.28 15:46
    Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By Martin Tesch from Lyon - 2018.06.28 19:27
    Write your message here and send it to us