PriceList for Bod Test Method - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We now have our own gross sales team, style and design workforce, technical crew, QC workforce and package group. We now have strict quality manage procedures for each system. Also, all of our workers are experienced in printing industry for Water Testing Equipment , Digital Nephelo Turbidity Meter , Sanitary Turbidity Meter , For more info, be sure to call us as shortly as possible!
PriceList for Bod Test Method - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua Detail:

Product Introduction

According to the national standard (HJ 505-2009) Water quality-Determination of biochemical oxygen demand after five days(BOD5) for dilution and seeding method, 12 samples once, safe and reliable mercury-free differential pressure sensing method (breathing method) is used to measure BOD in water, which completely simulates the biodegradation process of organic matter in nature. R&D process design and manufacturing, industry-leading function settings, fully intelligent design, unattended measurement process, automatic recording of data, completely saying goodbye to mercury poisoning caused by mercury leakage, is a BOD specially tailored for water quality analysis laboratories Professional analytical instruments.

Features

1) The method is safe and reliable: the mercury-free manometric method is adopted, no mercury pollution, and the data is accurate and reliable;

2) The measurement is independent and flexible: the test individual is independent, and the start time of a single sample can be determined at any time;

3) Color LCD screen: each test cap has a color LCD screen, which independently displays the test time, measurement results, sampling amount, etc.;

4) Control system: The microprocessor control system is used to automatically complete the measurement process without special care;

5) Wide range and optional: BOD value of (0~4000) mg/L can be determined without dilution;

6) Concentration direct reading: 1-12 samples can be measured without conversion, and the BOD concentration value can be directly displayed;

7) The mobility of the instrument is enhanced: each test cap has a built-in battery, and short-term power-off has no effect on the test, reducing the dependence on electric energy;

8) Large batch size: up to 12 samples can be measured at one time;

9) Easy to operate: only need a simple button to complete the setting, and the water sample can be bottled according to the volume set by the range to complete the test;

10) Automatic data recording: you can view the current experimental data at any time, as well as the five-day biochemical oxygen demand historical data;

11) Complete experimental accessories: equipped with all the reagents and accessories required for the experiment, which is convenient for accurate and fast sampling.

Specification

Product Name

Biochemical oxygen demand (BOD5 meter)

Model

LH-BOD1201

Accuracy

≤±5%

Range

(0~4000)mg/L

Minimum value

2mg/L

Volume

580mL

Repeatability

≤±5%

Samples

12 samples once

Data storage

5 and 7days

Period

5 and 7 optional

Dimension

(390×294×95)mm

Weight

6.5Kg

Test temperature

(20±1)℃

Environment humidity

≤85%RH (no condensation)

Supply

AC(100-240V)±10%/(50-60)Hz

Power

60W


Product detail pictures:

PriceList for Bod Test Method - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

PriceList for Bod Test Method - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

PriceList for Bod Test Method - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

PriceList for Bod Test Method - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

PriceList for Bod Test Method - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

PriceList for Bod Test Method - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

PriceList for Bod Test Method - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures


Related Product Guide:

We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for PriceList for Bod Test Method - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua , The product will supply to all over the world, such as: Italy, Portugal, Panama, The company has perfect management system and after-sales service system. We devote ourselves to building a pioneer in the filter industry. Our factory is willing to cooperate with different customers domestic and overseas to gain better and better future.
  • Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Honorio from Sydney - 2017.12.31 14:53
    Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Bess from United Arab emirates - 2017.02.28 14:19
    Write your message here and send it to us