We have been convinced that with joint attempts, the business enterprise between us will bring us mutual benefits. We could guarantee you product or service good quality and aggressive value for Online Turbidity Meter , Spectrum Cod Bod Tss , Multi Parameter Water Quality Field Test Kit , We always concertrating on developing new creative product to meet request from our clients all over the world. Join us and let's make driving safer and funnier together!
OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua Detail:

Product Introduction

It is important for wastewater treatment plants to measure Biochemical Oxygen Demand (BOD) to quantify the potential for effluent water to deplete the oxygen in the receiving stream. If not controlled, discharged wastewater can rob the receiving stream of this oxygen and have significant negative effects on the environment. Measuring BOD is required as part of the environmental discharge permit and is an important parameter to evaluate the effectiveness of the wastewater treatment operation.

LH-BOD601 BOD instrument with BOD reagent for Biochemical Oxygen Demand testing help wastewater treatment plants achieve optimum BOD measurement while allowing keeping a high level of operational efficiency. It is used manometric method, can choose 1-30 days testing period.

Functional characteristics

1. At the same time can be measured in a sample of 6.
2. Automatic daily print data.
3. Color liquid crystal display screen, the sample values with different colors, intuitive and clear.
4. Has a plurality of stirring mode (batch, continuous), prolong the service life of the instrument.
5. The culture period can be adjusted according to the demand, can choose 1-30 days.
6. To view the test process and the test data, no historical data.

Technical Parameters

Instrument name

Biochemical Oxygen Demand (BOD5) Instrument

Instrument model

LH-BOD601

Measurement range

0-4000mg/L

Measuring error

±5%

Record interval

6 minutes – 3 hours/time

Cycle length

1-30days

Measure amount

6

Culture bottle volume

580ml

Data storage

20 years

Communication

USB transmission, infrared transmission (optional)

Culture temperature

20±1

Working power

110-230V  50-60HZ

Rated power

24W

Advantage

● Wide measuring range 0-4000 mg/L
● Built-in thermal printer
● Intelligent analysis of data
● No reagents need for routine water sample testing

Usage

Sewage treatment plants, monitoring bureaus, environmental treatment companies, chemical plants, pharmaceutical plants, textile plants, university laboratories, food and beverage plants, etc.

FAQ

1. Are you a factory or trading company?
We are a factory.
2. MOQ?
We don’t have MOQ limit, you can order any quantity you want.
If you need it with your specification, logo, packing, etc, please negotiate with us.
3. Can I add my logo on the machine?
Yes,OEM is available for us.
4. How can i get the after-service?
We will send you the spare parts by free if the problems caused by us.
If it is the men-made problems,we also send the spare parts,but you should pay.
5. Do you have inspection procedures for these machine?
100% self-inspection before packing
6. Delivery date?
5-15 days
7. Payment Method?
L/C at sight, T/T, Credit card, paypal
8. Shipping?
a. International Experess: DHL/TNT/FEDEX/UPS (For sample)
b. By air (For sample orders.)
c. By sea (15-45days), port of loading: Shanghai
d. By domestic logistics to your forwarder. (2-3days)


Product detail pictures:

OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures

OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua detail pictures


Related Product Guide:

Normally customer-oriented, and it's our ultimate concentrate on for being not only one of the most dependable, trustable and honest supplier, but also the partner for our shoppers for OEM/ODM China Wastewater Bod - Manometric method BOD5 analyzer LH-BOD601SL – Lianhua , The product will supply to all over the world, such as: United States, New Zealand, Palestine, As a well educated, innovative and energetic staff,we are responsible for all elements of the research, design, manufacturing, sales and distribution. With studying and developing new techniques,we are not only following but also leading the fashion industry. We listen attentively to the feedback from our customers and provide instant communication. You will instantly feel our expertise and attentive service.
  • This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Arlene from Cape Town - 2018.06.18 17:25
    The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Andrea from Denver - 2018.09.08 17:09
    Write your message here and send it to us