Low MOQ for Bod Cod Water Analysis - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our development depends on the advanced equipment, excellent talents and continuously strengthened technology forces for Multi Parameter Water Testing Kit , Portable Precision Turbidimeter , Cod Measurement , We sincerely welcome both foreign and domestic business partners, and hope to work with you in the near future!
Low MOQ for Bod Cod Water Analysis - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua Detail:

Product Introduction

According to the national standard (HJ 505-2009) Water quality-Determination of biochemical oxygen demand after five days(BOD5) for dilution and seeding method, 12 samples once, safe and reliable mercury-free differential pressure sensing method (breathing method) is used to measure BOD in water, which completely simulates the biodegradation process of organic matter in nature. R&D process design and manufacturing, industry-leading function settings, fully intelligent design, unattended measurement process, automatic recording of data, completely saying goodbye to mercury poisoning caused by mercury leakage, is a BOD specially tailored for water quality analysis laboratories Professional analytical instruments.

Features

1) The method is safe and reliable: the mercury-free manometric method is adopted, no mercury pollution, and the data is accurate and reliable;

2) The measurement is independent and flexible: the test individual is independent, and the start time of a single sample can be determined at any time;

3) Color LCD screen: each test cap has a color LCD screen, which independently displays the test time, measurement results, sampling amount, etc.;

4) Control system: The microprocessor control system is used to automatically complete the measurement process without special care;

5) Wide range and optional: BOD value of (0~4000) mg/L can be determined without dilution;

6) Concentration direct reading: 1-12 samples can be measured without conversion, and the BOD concentration value can be directly displayed;

7) The mobility of the instrument is enhanced: each test cap has a built-in battery, and short-term power-off has no effect on the test, reducing the dependence on electric energy;

8) Large batch size: up to 12 samples can be measured at one time;

9) Easy to operate: only need a simple button to complete the setting, and the water sample can be bottled according to the volume set by the range to complete the test;

10) Automatic data recording: you can view the current experimental data at any time, as well as the five-day biochemical oxygen demand historical data;

11) Complete experimental accessories: equipped with all the reagents and accessories required for the experiment, which is convenient for accurate and fast sampling.

Specification

Product Name

Biochemical oxygen demand (BOD5 meter)

Model

LH-BOD1201

Accuracy

≤±5%

Range

(0~4000)mg/L

Minimum value

2mg/L

Volume

580mL

Repeatability

≤±5%

Samples

12 samples once

Data storage

5 and 7days

Period

5 and 7 optional

Dimension

(390×294×95)mm

Weight

6.5Kg

Test temperature

(20±1)℃

Environment humidity

≤85%RH (no condensation)

Supply

AC(100-240V)±10%/(50-60)Hz

Power

60W


Product detail pictures:

Low MOQ for Bod Cod Water Analysis - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Low MOQ for Bod Cod Water Analysis - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Low MOQ for Bod Cod Water Analysis - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Low MOQ for Bod Cod Water Analysis - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Low MOQ for Bod Cod Water Analysis - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Low MOQ for Bod Cod Water Analysis - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures

Low MOQ for Bod Cod Water Analysis - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua detail pictures


Related Product Guide:

We believe in: Innovation is our soul and spirit. Top quality is our life. Purchaser need is our God for Low MOQ for Bod Cod Water Analysis - Biochemical oxygen demand BOD5 meter LH-BOD1201 – Lianhua , The product will supply to all over the world, such as: Uruguay, Nigeria, Greece, We have sufficient experience in producing products according to samples or drawings. We warmly welcome customers from home and abroad to visit our company, and to cooperate with us for a splendid future together.
  • The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Miranda from America - 2017.09.28 18:29
    Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
    5 Stars By Page from Angola - 2018.07.26 16:51
    Write your message here and send it to us