Europe style for Chemical Instrument - BOD instrument manometric method LH-BOD601L – Lianhua

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We can always satisfy our respected customers with our good quality, good price and good service due to we are more professional and more hard-working and do it in cost-effective way for Seapoint Turbidity Sensor , Digestor , Multiparameter Meter , We sincerely welcome clients from both of those at your home and overseas to occur to barter business enterprise with us.
Europe style for Chemical Instrument - BOD instrument manometric method LH-BOD601L – Lianhua Detail:

Product Introduction

It is important for wastewater treatment plants to measure Biochemical Oxygen Demand (BOD) to quantify the potential for effluent water to deplete the oxygen in the receiving stream. If not controlled, discharged wastewater can rob the receiving stream of this oxygen and have significant negative effects on the environment. Measuring BOD is required as part of the environmental discharge permit and is an important parameter to evaluate the effectiveness of the wastewater treatment operation.

LH-BOD601L BOD instrument with BOD reagent for Biochemical Oxygen Demand testing help wastewater treatment plants achieve optimum BOD measurement while allowing keeping a high level of operational efficiency. It is used manometric method, and supports 1-7 days testing period.

Functional characteristics

1. At the same time can be measured in a sample of 6.
2. Automatic daily print data.
3. Color liquid crystal display screen, the sample values with different colors, intuitive and clear.
4. Has a plurality of stirring mode (batch, continuous), prolong the service life of the instrument. 
5. The culture period can be adjusted according to the demand, can choose 1-30 days.
6. To view the test process and the test data, no historical data.

Technical Parameters

Instrument name Biochemical Oxygen Demand (BOD5) Instrument
Instrument model LH-BOD601L
Measurement range 0-4000mg/L
Measuring error ±5%
Cycle length 1-7days
Measure amount 6
Culture bottle volume 580ml
Data storage 5 years
Communication USB transmission, infrared transmission (optional)
Culture temperature 20±1
Working power 110-230V  50-60HZ
Rated power 24W

Advantage

● Wide measuring range 0-4000 mg/L
● Built-in thermal printer
● Intelligent analysis of data
● No reagents need for routine water sample testing

Usage

Sewage treatment plants, monitoring bureaus, environmental treatment companies, chemical plants, pharmaceutical plants, textile plants, university laboratories, food and beverage plants, etc.

FAQ

1. Are you a factory or trading company?
We are a factory.
2. MOQ?
We don’t have MOQ limit, you can order any quantity you want.
If you need it with your specification, logo, packing, etc, please negotiate with us.
3. Can I add my logo on the machine?
Yes,OEM is available for us.
4. How can i get the after-service?
We will send you the spare parts by free if the problems caused by us.
If it is the men-made problems,we also send the spare parts,but you should pay.
5. Do you have inspection procedures for these machine?
100% self-inspection before packing
6. Delivery date?
5-15 days
7. Payment Method?
L/C at sight, T/T, Credit card, paypal
8. Shipping?
a. International Experess: DHL/TNT/FEDEX/UPS (For sample)
b. By air (For sample orders.)
c. By sea (15-45days), port of loading: Shanghai
d. By domestic logistics to your forwarder. (2-3days)


Product detail pictures:

Europe style for Chemical Instrument - BOD instrument manometric method LH-BOD601L – Lianhua detail pictures

Europe style for Chemical Instrument - BOD instrument manometric method LH-BOD601L – Lianhua detail pictures

Europe style for Chemical Instrument - BOD instrument manometric method LH-BOD601L – Lianhua detail pictures

Europe style for Chemical Instrument - BOD instrument manometric method LH-BOD601L – Lianhua detail pictures

Europe style for Chemical Instrument - BOD instrument manometric method LH-BOD601L – Lianhua detail pictures


Related Product Guide:

Our advancement depends over the superior machines, exceptional talents and continually strengthened technology forces for Europe style for Chemical Instrument - BOD instrument manometric method LH-BOD601L – Lianhua , The product will supply to all over the world, such as: Islamabad, Myanmar, Las Vegas, The company has perfect management system and after-sales service system. We devote ourselves to building a pioneer in the filter industry. Our factory is willing to cooperate with different customers domestic and overseas to gain better and better future.
  • The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Marjorie from USA - 2018.04.25 16:46
    The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Diana from Korea - 2018.10.31 10:02
    Write your message here and send it to us